Timer Instructions
Steady Stream DrainPro System — Model T200. Configure your DrainPro's built-in timer for optimal performance and efficiency.
Factory Pre-Programmed Setting
Timer is pre-programmed to run weekly on Saturdays at 1:00 PM EST (13:00).
⚠️ WARNING: AUTO Mode Setting
Do not use AUTO mode (WITH LIGHT BULB SYMBOL) for more than 2 minutes. Always keep timer on AUTO mode (NO light bulb symbol) to ensure proper functionality of the programs, as this will automatically turn on the pump.
Step-by-Step Timer Setup
Blank Screen
If the timer display screen is blank, the pump MAY TURN ON once the unit has power. Press and release the C "reset" button, using a small pointed object (example: pen or paper clip). Follow the instructions below to set the timer.
Confirm Correct Day/Time
Confirm timer has power and is displaying the correct day/time. AUTO mode (NO light bulb symbol) should be visible on the screen prior to connecting Steady Stream to power source. If the screen shows OFF, ON or AUTO (WITH light bulb symbol) press MANUAL button until AUTO (NO light bulb symbol) is selected.
Set Day/Time
Press and hold clock button while pressing D + (days), H + (hours) or M + (minutes); release clock button when completed. Press clock button or wait 30 seconds to return to main menu. Time is displayed in 24 hour format.
Change Day/Time
Press P button to display 1ON, then set day/time. Next press P button to display 1OFF, repeat previous step to set off day/time.
Add ON/OFF Times
Press P button three times to display 2ON, then set day/time. Press P button to display 2OFF, repeat step to set day, time and minutes. Repeat steps for additional times.
Remove ON/OFF Times
Press P button until ON time to be removed is displayed. Press C/R button to remove ON time. Next press P button to display OFF time then press C/R button to remove it. Repeat steps to remove additional times.
Button Reference Guide
Quick Tips
24-Hour Format
Time is displayed in 24-hour format. For example, 1:00 PM is displayed as 13:00.
Auto Return
Press clock button or wait 30 seconds to automatically return to main menu after making changes.
Multiple Programs
You can set multiple ON/OFF times by using the P button to navigate to 2ON, 3ON, etc.
Reset Option
If the screen is blank, press the C "reset" button with a pen or paper clip to restart the timer.